首站-论文投稿智能助手
典型文献
Experimental study of single-translated field-reversed configuration in KMAX
文献摘要:
For collisional merging field-reversed configurations(FRCs),it is desired to have both FRCs tuned to be approximately the same,as well as to optimize each FRC to have high temperature and high translation speed so as to retain most of the equilibrium flux after traveling a distance to the middle plane for merging.The present study reports the experimental study of a single-translated FRC in the KMAX-FRC device with various diagnostics,including a triple probe,a bolometer,several magnetic probe arrays,and a novel 2D internal magnetic probe array.According to the measurements conducted in the present study,a maximum toroidal magnetic field equal to~1/3 of the external magnetic field inside the FRC separatrix radius is observed,and the typical parameters of a single-translated FRC near the device's mid-plane are ne~(2-4)×1019 m-3,Te~8 eV,Ti~5 eV,rs~0.2 m,ls~0.6 m and ?p(RR)~0.2 mWb.The 2D magnetic topology measurement revealed,for the first time,the time evolution of the overall internal magnetic fields of a single-translated FRC,and an optimized operation regime is given in the paper.
文献关键词:
作者姓名:
Hui LIAO;Chaoqi HU;Yilin LI;Baoming REN;Xuan SUN
作者机构:
Department of Plasma Physics and Fusion Engineering,School of Nuclear Science and Technology,University of Science and Technology of China,Hefei 230026,People's Republic of China
引用格式:
[1]Hui LIAO;Chaoqi HU;Yilin LI;Baoming REN;Xuan SUN-.Experimental study of single-translated field-reversed configuration in KMAX)[J].等离子体科学和技术(英文版),2022(09):37-44
A类:
KMAX,FRCs,bolometer,mWb
B类:
Experimental,study,single,translated,reversed,For,collisional,merging,configurations,desired,have,both,tuned,approximately,same,well,each,high,temperature,translation,speed,so,retain,most,equilibrium,flux,after,traveling,distance,middle,plane,present,reports,experimental,device,various,diagnostics,including,triple,probe,several,magnetic,arrays,novel,2D,internal,According,measurements,conducted,maximum,toroidal,equal,external,inside,separatrix,radius,observed,typical,parameters,near,are,Te,eV,Ti,ls,RR,topology,revealed,first,evolution,overall,fields,optimized,operation,regime,given,paper
AB值:
0.478431
相似文献
Mid-infrared active metasurface based on Si/VO2 hybrid meta-atoms
TONGTONG KANG;BOYU FAN;JUN QIN;WEIHAO YANG;SHUANG XIA;ZHENG PENG;BO LIU;SUI PENG;XIAO LIANG;TINGTING TANG;LONGJIANG DENG;YI LUO;HANBIN WANG;QIANG ZHOU;LEI BI-National Engineering Research Center of Electromagnetic Radiation Control Materials,University of Electronic Science and Technology of China,Chengdu 610054,China;State Key Laboratory of Electronic Thin-Films and Integrated Devices,University of Electronic Science and Technology of China,Chengdu 610054,China;Institute of Fundamental and Frontier Sciences,University of Electronic Science and Technology of China,Chengdu 610054,China;College of Optoelectronic Engineering,Chengdu University of Information Technology,Chengdu 610225,China;State Key Laboratory of Vanadium and Titanium Resources Comprehensive Utilization,Panzhihua 617000,China;Microsystem&Terahertz Research Center,China Academy of Engineering Physics(CAEP),Chengdu 610200,China;Institute of Electronic Engineering,China Academy of Engineering Physics(CAEP),Mianyang 621900,China
Dynamic nitrogen vacancy magnetometry by single-shot optical streaking microscopy
Mark A. Keppler;Zachary A. Steelman;Zachary N. Coker;Milo? Nesládek;Philip R. Hemmer;Vladislav V. Yakovlev;Joel N. Bixler-Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA;SAIC, JBSA Fort Sam Houston, Texas 78234, USA;National Research Council Research Associateship Program, Washington, DC 20001, USA;IMOMEC Division, IMEC, B-3590 Diepenbeek, Belgium;Institute for Materials Research (IMO), Hasselt University, B-3590 Diepenbeek, Belgium;Czech Technical University in Prague, 27201 Kladno, Czech Republic;Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, USA;Bioeffects Division, Airman System Directorate, Air Force Research Laboratory, JBSA Fort Sam Houston, Texas 78234, USA;e-mail: yakovlev@tamu.edu
Dynamic nitrogen vacancy magnetometry by single-shot optical streaking microscopy
MARK A.KEPPLER;ZACHARY A.STEELMAN;ZACHARY N.COKER;MILO? NESLáDEK;PHILIP R.HEMMER;VLADISLAV V.YAKOVLEV;JOEL N.BIXLER-Department of Biomedical Engineering,Texas A&M University,College Station,Texas 77843,USA;SAIC,JBSA Fort Sam Houston,Texas 78234,USA;National Research Council Research Associateship Program,Washington,DC 20001,USA;IMOMEC Division,IMEC,B-3590 Diepenbeek,Belgium;Institute for Materials Research(IMO),Hasselt University,B-3590 Diepenbeek,Belgium;Czech Technical University in Prague,27201 Kladno,Czech Republic;Department of Electrical and Computer Engineering,Texas A&M University,College Station,Texas 77843,USA;Bioeffects Division,Airman System Directorate,Air Force Research Laboratory,JBSA Fort Sam Houston,Texas 78234,USA
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。