New ultrashort pulsewidth measurement technology based on interference jitter and FPGA platform
文献摘要:
Conventional ultrashort pulsewidth measurement technology is autocorrelation based on second-harmonic generation;however,nonlinear crystals and bulky components are required,which usually leads to the limited wavelength range and the difficult adjustment with free-space light alignment.Here,we proposed a compact all-fiber pulsewidth measure-ment technology based on the interference jitter[IJ]and field-programmable gate array[FPGA]platform,without requiring a nonlinear optical device[e.g.,nonlinear crystal/detector].Such a technology shows a wide measurement waveband from 1 to 2.15 μm at least,a pulsewidth range from femtoseconds to 100 ps,and a small relative error of 0.15%-3.8%.In particular,a minimum pulse energy of 219 fJ is experimentally detected with an average-power-peak-power product of 1.065×10-6 W2.The IJ-FPGA technology may offer a new route for miniaturized,user-friendly,and broadband pulsewidth measurement.
文献关键词:
作者姓名:
Jin Li;Yanbo Dou;Lixin Wang;Jinhai Zou;Yu Ding;Hang Wang;Qiujun Ruan;Zhipeng Dong;Zhengqian Luo
作者机构:
Department of Electronic Engineering,Xiamen University,Xiamen 361005,China;Science and Technology on Electro-Optical Information Security Control Laboratory,Tianjin 300308,China
引用格式:
[1]Jin Li;Yanbo Dou;Lixin Wang;Jinhai Zou;Yu Ding;Hang Wang;Qiujun Ruan;Zhipeng Dong;Zhengqian Luo-.New ultrashort pulsewidth measurement technology based on interference jitter and FPGA platform)[J].中国光学快报(英文版),2022(03):46-51
A类:
pulsewidth
B类:
New,ultrashort,measurement,technology,interference,jitter,FPGA,platform,Conventional,is,autocorrelation,harmonic,generation,however,nonlinear,crystals,bulky,components,are,required,which,usually,leads,limited,wavelength,range,difficult,adjustment,free,space,light,alignment,Here,proposed,compact,fiber,IJ,field,programmable,gate,array,without,requiring,optical,device,detector,Such,shows,wide,waveband,from,least,femtoseconds,ps,small,relative,error,In,particular,minimum,energy,fJ,experimentally,detected,average,power,peak,product,W2,may,offer,new,route,miniaturized,user,friendly,broadband
AB值:
0.614502
相似文献
Soliton formation and spectral translation into visible on CMOS-compatible 4H-silicon-carbide-on-insulator platform
Chengli Wang;Jin Li;Ailun Yi;Zhiwei Fang;Liping Zhou;Zhe Wang;Rui Niu;Yang Chen;Jiaxiang Zhang;Ya Cheng;Junqiu Liu;Chun-Hua Dong;Xin Ou-State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,200050 Shanghai,China;The Center of Materials Science and Optoelectronics Engineering,University of Chinese Academy of Sciences,100049 Beijing,China;CAS Key Laboratory of Quantum Information,University of Science and Technology of China,230026 Hefei,China;CAS Center for Excellence in Quantum Information and Quantum Physics,University of Science and Technology of China,230026 Hefei,China;The Extreme Optoelectromechanics Laboratory(XXL),School of Physics and Electronic Science,East China Normal University,200241 Shanghai,China;State Key Laboratory of High Field Laser Physics and CAS Center for Excellence in Ultra-intense Laser Science,Shanghai Institute of Optics and Fine Mechanics,Chinese Academy of Sciences,201800 Shanghai,China;International Quantum Academy,518048 Shenzhen,China;Hefei National Laboratory,University of Science and Technology of China,Hefei 230026,China
Spectrally tunable high-power Yb∶fiber chirped-pulse amplifier
VALENTINA SHUMAKOVA;VITO F.PECILE;JAKOB FELLINGER;MICHAEL LESKOWSCHEK;P.E.COLLIN ALDIA;ALINE S.MAYER;LUKAS W.PERNER;SARPER SALMAN;MINGQI FAN;PRANNAY BALLA;STéPHANE SCHILT;CHRISTOPH M.HEYL;INGMAR HARTL;GIL PORAT;OLIVER H.HECKL-Christian Doppler Laboratory for Mid-IR Spectroscopy and Semiconductor Optics,Faculty Center for Nano Structure Research,Faculty of Physics,University of Vienna,A-1090 Vienna,Austria;Photonics Institute,TU Wien,A-1040 Vienna,Austria;Vienna Doctoral School in Physics,University of Vienna,A-1090 Vienna,Austria;Deutsches Elektronen-Synchrotron DESY,22607 Hamburg,Germany;Laboratoire Temps-Fréquence,Université de Neuchatel,CH-2000 Neuchatel,Switzerland;GSI Helmholtzzentrum für Schwerionenforschung GmbH,64291 Darmstadt,Germany;Helmholtz-Institute Jena,07743 Jena,Germany;Department of Electrical and Computer Engineering,University of Alberta,Edmonton,Alberta T6G 1H9,Canada;Department of Physics,University of Alberta,Edmonton,Alberta T6G 2E1,Canada
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。