文献摘要:
Chemiluminescence immunoassay(CLIA)has always been a great challenge in detecting cardiac tro-ponin Ⅰ(cTnI)in whole blood samples without centrifugation because of the interference of red blood cells and low sensitivity.In this study,the antigens and erythrocytes in the blood were captured by the antibodies immobilized on the magnetic particles,recognized by another biotin-conjugated cTnI antibody and detected by streptavidin/acridine aster-conjugated polychloromethyl-styrene microspheres(PCMS).After magnetic separation,the supernatant was transferred and mea-sured.No significant difference was noted between the cTnI concentrations of the serum samples,plasma samples and whole blood.The prepared PCMS provided more functional areas to conjugate streptavidin and acridinium ester,so the immunoassay has highly sensitive,the limits of blank at 0.012 ng/mL,and functional sensitivity at 0.019 ng/mL with a CV of 20%,and 0.058 ng/mL with a CV of 10%.Total precision of any sample type ranged from 2.62%~5.67%.The assay was linear over the stud-ied range of 0.01-50.00 ng/mL,and no hook effect was found when cTnI concentrations reached 1900 ng/mL.No significant interference was noted with the potential endogenous interfering substances.Com-pared with the commercial kit(Abbott assay kit),the correlation coefficient was 0.9859.A washing-free CLIA was established for the rapid detection of cTnI in human whole blood,using erythrocyte capture antibodies-conjugated magnetic nanoparticles for eliminating the influence of erythrocytes and PCMS for signal amplification,which showed great potential in clinical application.
文献关键词:
中图分类号:
作者姓名:
Huan Zhao;Enben Su;Li Huang;Yunfeng Zai;Yuan Liu;Zhu Chen;Song Li;Lian Jin;Yan Deng;Nongyue He
作者机构:
State Key Laboratory of Bioelectronics,National Demonstration Center for Experimental Biomedical Engineering Education,School of Biological Science and Medical Engineering,Southeast University,Nanjing 210096,China;Getein Biotechnology Co.,Ltd.,Nanjing 210000,China;Hunan Key Laboratory of Biomedical Nanomaterials and Devices,Hunan University of Technology,Zhuzhou 412007,China
文献出处:
引用格式:
[1]Huan Zhao;Enben Su;Li Huang;Yunfeng Zai;Yuan Liu;Zhu Chen;Song Li;Lian Jin;Yan Deng;Nongyue He-.Washing-free chemiluminescence immunoassay for rapid detection of cardiac troponin Ⅰ in whole blood samples)[J].中国化学快报(英文版),2022(02):743-746
A类:
Chemiluminescence,tro,ponin,polychloromethyl,acridinium
B类:
Washing,free,chemiluminescence,immunoassay,rapid,detection,cardiac,troponin,whole,blood,samples,CLIA,has,always,been,great,challenge,detecting,cTnI,without,centrifugation,because,interference,cells,low,sensitivity,In,this,study,antigens,erythrocytes,were,captured,by,antibodies,immobilized,magnetic,recognized,another,biotin,conjugated,antibody,detected,streptavidin,acridine,aster,styrene,microspheres,PCMS,After,separation,supernatant,transferred,mea,sured,No,significant,difference,noted,between,concentrations,serum,plasma,prepared,provided,more,functional,areas,ester,so,highly,sensitive,limits,blank,CV,Total,precision,any,type,ranged,from,linear,over,ied,hook,effect,found,when,reached,potential,endogenous,interfering,substances,Com,commercial,kit,Abbott,correlation,coefficient,washing,established,human,using,nanoparticles,eliminating,influence,signal,amplification,which,showed,clinical,application
AB值:
0.53171
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。