典型文献
The airborne contagiousness of respiratory viruses:A comparative analysis and implications for mitigation
文献摘要:
The infectious emission rate is a fundamental input parameter for airborne transmission risk assessment,but data are limited due to reliance on estimates from chance superspreading events.This study assesses the strength of a predictive estimation approach developed by the authors for SARS-CoV-2 and uses novel estimates to compare the contagiousness of respiratory pathogens.We applied the approach to SARS-CoV-1,SARS-CoV-2,MERS,measles virus,adenovirus,rhinovirus,coxsackievirus,seasonal influenza virus and Mycobacterium tuberculosis(TB)and compared quanta emission rate(ERq)estimates to literature val-ues.We calculated infection risk in a prototypical classroom and barracks to assess the relative ability of ventilation to mitigate airborne transmission.Our median standing and speaking ERq estimate for SARS-CoV-2(2.7 quanta h-1)is similar to active,untreated TB(3.1 quanta h-1),higher than seasonal influenza(0.17 quanta h-1),and lower than measles virus(15 quanta h-1).We calculated event reproduction num-bers above 1 for SARS-CoV-2,measles virus,and untreated TB in both the classroom and barracks for an activity level of standing and speaking at low,medium and high ventilation rates of 2.3,6.6 and 14 L per second per person(L s-1 p-1),respectively.Our predictive ERq estimates are consistent with the range of values reported over decades of research.In congregate settings,current ventilation standards are unli-kely to control the spread of viruses with upper quartile ERq values above 10 quanta h-1,such as SARS-CoV-2,indicating the need for additional control measures.
文献关键词:
中图分类号:
作者姓名:
Alex Mikszewski;Luca Stabile;Giorgio Buonanno;Lidia Morawska
作者机构:
International Laboratory for Air Quality and Health,Queensland University of Technology,Brisbane,Queensland,Australia;CIUS Building Performance Lab,The City University of New York,New York,NY,USA;Department of Civil and Mechanical Engineering,University of Cassino and Southern Lazio,Cassino,FR,Italy;Global Centre for Clean Air Research(GCARE),Department of Civil and Environmental Engineering,Faculty of Engineering and Physical Sciences,University of Surrey,Guildford GU2 7XH,United Kingdom
文献出处:
引用格式:
[1]Alex Mikszewski;Luca Stabile;Giorgio Buonanno;Lidia Morawska-.The airborne contagiousness of respiratory viruses:A comparative analysis and implications for mitigation)[J].地学前缘(英文版),2022(06):257-264
A类:
contagiousness,ERq,barracks,congregate,unli,kely
B类:
airborne,respiratory,viruses,comparative,analysis,implications,mitigation,infectious,emission,fundamental,input,parameter,transmission,risk,assessment,but,data,limited,due,reliance,estimates,from,chance,superspreading,events,This,study,assesses,strength,predictive,estimation,approach,developed,by,authors,SARS,CoV,novel,pathogens,We,applied,MERS,measles,adenovirus,rhinovirus,coxsackievirus,seasonal,influenza,Mycobacterium,tuberculosis,TB,compared,quanta,literature,calculated,infection,prototypical,classroom,relative,ability,ventilation,mitigate,Our,median,standing,speaking,similar,active,untreated,higher,than,lower,reproduction,num,bers,above,both,activity,level,medium,rates,second,person,respectively,consistent,range,values,reported,over,decades,research,In,settings,current,standards,control,upper,quartile,such,indicating,need,additional,measures
AB值:
0.469508
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。