典型文献
Monte Carlo simulation for performance evaluation of detector model with a monolithic LaBr3(Ce)crystal and SiPM array for γ radiation imaging
文献摘要:
In recent years,LaBr3(Ce)crystals and silicon photomultipliers(SiPMs)have been increasingly used in radiation imaging.This study involved the establishment of a detector model with a monolithic LaBr3(Ce)crystal and SiPM array for γ-radiation imaging on the GEANT4 plat-form.The optical process included in the detector model was defined by key parameters,such as the emission spectrum,scintillation yield,and intrinsic resolution of the LaBr3:5%Ce crystal,as well as the detection efficiency of the SiPM array.The response of the detector model to 57Co flooded field irradiation was simulated and evaluated.The radiation images generated by the detector model exhibited a compression effect that was very close to that on images acquired by the physical detector.The spatial resolution of the simulated detector closely approximates that of the physical experiment.A detector model without the optical process was also established for comparison with a detector using the optical process.Both were used in a near-field modified uniform redundant array(MURA)imaging system to acquire images of a point source and a ring source of57Co at the center of the field-of-view of the imaging system.The spatial resolution and signal-to-noise ratio of the images that were reconstructed using the two detector models were determined and compared.Compared with the detector model without optical processes,although the images from the proposed detector model have slightly inferior signal-to-noise ratios and more artifacts,they are more consistent with the reconstructed versions of images acquired in real physical experiments.The results confirm that the detector model can be used to design a γ-radiation imaging detector and to develop an imaging algorithm that can significantly shorten the development time and reduce the cost.
文献关键词:
中图分类号:
作者姓名:
Wei Lu;Lei Wang;Yong Yuan;Ting Zhang;Ge Tang;Ming-Zhe Liu;Xian-Guo Tuo;Jing Ning
作者机构:
Chengdu University of Technology,Chengdu 610059,China;Beijing Institute of Radiation Medicine,Beijing 100850,China;Sichuan University of Science and Engineering,Zigong 643000,China
文献出处:
引用格式:
[1]Wei Lu;Lei Wang;Yong Yuan;Ting Zhang;Ge Tang;Ming-Zhe Liu;Xian-Guo Tuo;Jing Ning-.Monte Carlo simulation for performance evaluation of detector model with a monolithic LaBr3(Ce)crystal and SiPM array for γ radiation imaging)[J].核技术(英文版),2022(08):163-174
A类:
photomultipliers,SiPMs,57Co,of57Co
B类:
Monte,Carlo,simulation,performance,evaluation,detector,monolithic,LaBr3,Ce,array,imaging,In,recent,years,crystals,silicon,have,been,increasingly,used,This,study,involved,establishment,GEANT4,plat,optical,included,was,defined,by,key,parameters,such,emission,spectrum,scintillation,yield,intrinsic,resolution,well,detection,efficiency,response,flooded,field,irradiation,simulated,evaluated,images,generated,exhibited,compression,effect,that,very,acquired,physical,spatial,closely,approximates,without,also,established,comparison,using,Both,were,near,modified,uniform,redundant,MURA,system,point,source,ring,center,view,signal,noise,reconstructed,two,models,determined,compared,Compared,processes,although,from,proposed,slightly,inferior,ratios,more,artifacts,they,consistent,versions,real,experiments,results,confirm,design,algorithm,significantly,shorten,development,reduce,cost
AB值:
0.425603
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。